Mercury ES - Operator Workstations
Product No. 700-25-01-10005
The Mercury ES operator workstation provides users with up to 32 simultaneous IP audio channels for communications with other authorized Mercury ES operators, radios and telephones. The workstation includes a Mercury Interface Unit, DSP expansion to 32 IP audio channels, and an Audio Expansion Board. Mercury ES Workstation to Workstation Communications over the Mercury ES Voice Bridge |
|
![]() |
|
The diagram above shows two Mercury ES Workstations communicating over a Mercury ES Voice Bridge. |
|
Specifications
| Integrated User Interface | |
| Type | Browser Panel |
| Input / Output Connections (Standard) | |
| Auxiliary Audio: | Mic In, Headphone Out on the front panel; CD In, Aux Out on rear panel |
| PS/2 Ports: | Two (2) for keyboard and mouse |
| Serial Ports: | Three (3) (2 RS-232, 1 RS-232/422) |
| Graphics: | SVGA (800x600 or better) - used for set-up only |
| USB Ports: | Two (2) (1-front, 1 rear) |
| Ethernet: | Mode 1: 2 x Independent Connections (NET and AUX.NET) for control of voice traffic; Mode 2: 1 x Combined Connection (AUX.NET) via internal switch |
| Physical Characteristics | |
| Height: | 89 mm or 3.5 in. |
| Length: | 370 mm or 14.5 in. excluding connectors and power supply handle; 408 mm or 16 in. including connectors and power supply handle td> |
| Width: | 483 mm or 19.01 in. including rackmount ears; 450 mm or 17.01 excluding rackmount ears |
| Weight: | Up to 6 kg or 13.5 lbs. fully equipped |
| Electrical Characteristics | |
| Standard Power Supply | 125W Commercial Power Supply |
| Nominal Input Voltage: | 100 - 264 VAC |
| Maximum AC Input: | 90 - 264 VAC |
| Frequency: | 47-63 Hz |
| MTBF: | 200,000 hours |
| Connector Type: | IEC Mains Connector with Retainer |
| Redundancy Options | Single or (optional) dual PSU configuration Internally Fused 2A (F) 250V |
| Environmental Characteristics | |
| Temperature, Operating: | 0° to 50° Celsius |
| Temperature, Non Operational/Storage: | -20° to 85° Celsius |
| Humidity, Operating: | Relative Humidity 0 to 90 percent, non-condensing |
| Altitude: | 4,000m (Has performed successfully at an altitude of 54,000 ft. in an unpressurized environment) |
| Shock: | 800g/1mS |
| Vibration: | 5.0g (22 to 500Hz) |
| Regulatory Compliance | |
| Regulatory Compliance | Radiated and Conducted Emissions FCC Part 15, Subpart B; EN61000-6-1 Safety: CSA 60950-1-03; UL 60950-1; IEC 60950 |